<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-22 14-29-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.70 MHz 5/5, 57 dBuV ZUERISEE
Pilot RDS Phase Difference
6.5 kHz 2.2 kHz 87 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 58 kHz 18651 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,2 dBr 2,40 dBr 2,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ZUERISEE" 4F14 10 (Pop M) 1 0 1 1 --:--
RT
-
AF EON
88.4, 106.7 MHz -
FM Scope Max at: 58 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2026.09.22 14.28.03 Total samples: 18651 Equivalent time: 0:15:32 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 2,5 dBr MIN: 2,2 dBr AVE: 2,40 dBr % above 12,2 dBr: 0,0 Last value: 2,4 dBr (2026.09.22 14.28.03) 14.14 14.16 14.18 14.20 14.22 14.24 14.26 14.28 -1 0 1 2 3 Pm [dBr]